BY- Dreamy-C-20C

BY- Dreamy-C-20C
Description
ResPlus series CPAP machine is our second generation CPAP Device. Its working mode includes CPAP, APAP, S, S/T, T, APCV, AND Auto B, and the color consists of gray white and black gray. The screen adopts 3.5" TFT LCD display.




















Specification of ResPlus Series CPAP Machine
Name CPAP BIPAP
Model C-20C C-20A B-20S B-20A B-20T B-25S B-25A B-25T B-25P B-30S B-30A B-30T B-30P
Color Gray white Black gray
Screen 3.5" TFT LCD display
Working mode
CPAP
APAP - - - - - - - -
S - -
S/T - - - - - - - -
T - - - - - - - -
APCV - - - - - - - - - - -
Auto B - - - - - - - - - -
Weight ( host+humidifier) With humidifier: 2.2kg
Without humidifier: 1.2kg
Dimension With humidifier: 280mm×200mm×112mm
Without humidifier: 145mm×200mm×112mm
Working dB (Sound Pressure Level) <30dBA(working at 10cmH2O)
Parameter Setting
Pressure Range
Pressure (cmH2O) 4--20 4--20 - - - - - - - - - - -
Initial Pressure (cmH2O) 4--20 4--20 4--18 4--18 4--18 4--23 4--23 4--23 4--23 4--25 4--25 4--25 4--25
Max Pressure (cmH2O) - 4--20 - - - - - - - - - - -
Min Pressure (cmH2O) - 4--20 - - - - - - - - - - -
Inhalation Pressure (cmH2O) - - 4--20 4--20 4--20 4--25 4--25 4--25 4--25 4--30 4--30 4--30 4--30
Exhalation Pressure (cmH2O) - - 4--18 4--18 4--18 4--23 4--23 4--23 4--23 4--25 4--25 4--25 4--25
Max Inhalation Pressure (cmH2O) - - - 4--18 - - 4--25 - - - 4--30 - -
Min Exhalation Pressure (cmH2O) - - - 4--18 - - 4--23 - - - 4--25 - -
Max Support Pressure (cmH2O) - - - 2--8 - - 2--8 - - - 2--8 - -
Inhalation Sensitivity (Auto, 1-6 level) - -
Exhalation Sensitivity (Auto, 1-6 level) - -
Pressure Rising Time (1-6 level) - -
Respiratory Rate (4-40bpm) - - - - - - - -
Inhalation Time (0.5-4s) - - - - - - - -
Max/Min Inhalation Time -4S - -
Min Inhalation Time (0.5-4s) - -
Volume Assurance Function(VAF) - - - - -
Target VT (50-2000ml) - - - - -
95th Titration - - - - - - - - -
Ramp (Off,1-60 minutes)
Automatic On
Automatic Off
Parameter Monitor
Pressure Monitor
Airflow Monitor
VT Monitor - -
Liters Per Minute Monitor - -
Leakage Monitor - -
Respiratory Rate Monitor - -
Inhalation Time Monitor - -
AC Power Consumption (110V-240V)
Automatic Leakage Compensation
Automatic Altitude Compensation
Alert
Power Failure
Low Input Voltage
Airway Obstructed
High Leak
Humidifier Failure
TF Card Full
High Pressure - -
Low Pressure - -
Liters Per Minute is Low - -
Please Change Filter - -
Humidifier
Data Record
Data Transmit: TF Card
Statistics
Detailed Data